Description
Product Information
- Family Brand Name: OCTRON® XP® CURVALUME® SUPERSAVER® ECOLOGIC®
- Nominal Voltage (V): 137.00
- Color Rendering Index (CRI): 85
- Nominal Wattage (W): 30.00
- Abbrev. With Packaging Info.: FBO30830XP6SSECO 137V 16/CS 1/SKU
- Color Temperature/CCT (K): 3000
- Initial Lumens at 25C: 2800
- Bulb: T8
- Average Rated Life (hr): 24000
- Base: Medium Bipin
Additional Product Information
Packaging Information
Product Documents, Graphs, and Images
Product Information Bulletin - OCTRON CURVALUME ECOLOGIC T8 LampsFootnotes
- SYLVANIA ECOLOGIC fluorescent lamps are designed to pass the Federal Toxic Characteristic Leaching Procedure (TCLP) criteria for classification as non-hazardous waste in most states. TCLP test results are available upon request. Lamp disposal regulations may vary, check your local & state regulations. For more information, please visit www.lamprecycle.org
- Recommended to be used on any F32 T8 Instant Start circuit. It is not recommended to be used:(1) with Rapid Start circuits unless the open circuit voltage is greater than 550V, (2) at lamp ambient temperatures below 60 degrees F or in drafty locations, (3) on dimming ballast or (4) inverter operated emergency lighting systems unless any of the above equipment is specifically listed for use with the OCTRON(R) SUPERSAVER(R) 28 or 30 watt, 4 foot or 30W U-bent T8 lamp. Any of the above situations could result in lamp starting and stabilization problems
- This lamp may also be operated by the OSRAM SYLVANIA QUICKTRONIC(R) PSN ballast (.88 BF), or the QUICTRONIC PSX ballast (.71 BF).
- Approximate initial lumens after 100 hours operation.
- The lamp lumen maintenance factor used to determine the mean lumen value was 95%. This is the lamp lumen maintenance factor at 8,000 hours, 40% of 20,000 hours. It was used to allow comparison to standard OCTRON(R) lamps with an average rated life of 20,000 hours. The lamp lumen maintenance factor at 40% of the 24,000 hour average rated life of this lamp, 9600 hours, would be 94%.*
- Approximate length of OCTRON CURVALUME lamps is measured from base face to outside of glass bend.
- Life rating of OCTRON XP lamps operated on instant start electronic ballasts is 18,000 hours based on the industry standard life test cycle of 3 hours per start.
- The life ratings of fluorescent lamps are based on 3 hr. burning cycles under specified conditions and with ballast meeting ANSI specifications. If burning cycle is increased, there will be a corresponding increase in the average hours life.