{"product_id":"occupancy-sensor-pir-wall-switch-2100sf-120-277v-black-auto-on-auto-off-only-decora-r","title":"Occupancy Sensor, PIR, Wall Switch, 2100SF, 120-277V, Black, Auto-ON\/Auto-OFF Only, Decora®","description":"\u003ch2\u003eOccupancy Sensor, PIR, Wall Switch, 2100SF, 120-277V, Black, Auto-ON\/Auto-OFF Only, Decora¬Æ Lighting Control\u003c\/h2\u003e\n\n\u003cp\u003eThis Leviton occupancy sensor is a passive infrared (PIR) wall switch designed for automatic lighting control in commercial and residential applications. It detects occupancy within a 2100 square foot area and operates on a wide voltage range of 120 to 277VAC, making it suitable for various electrical distributor and lighting solutions environments. The device offers Auto-ON\/Auto-OFF functionality without manual override and includes photocell control to prevent lights from turning on in sufficient ambient light conditions. Its low-profile design and adjustable blinders provide flexible installation options for switchgear suppliers and wire and cable professionals seeking efficient energy management.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCoverage Area: 2100 sq ft\u003c\/li\u003e\n  \u003cli\u003eVoltage: 120\/208\/220\/230\/240\/277VAC, 50\/60Hz\u003c\/li\u003e\n  \u003cli\u003eField of View: 180 degrees\u003c\/li\u003e\n  \u003cli\u003eTime Delay: Adjustable, 30 seconds to 30 minutes\u003c\/li\u003e\n  \u003cli\u003eColor: Black\u003c\/li\u003e\n  \u003cli\u003eProduct Weight: 3.2 lbs\u003c\/li\u003e\n  \u003cli\u003eCertifications: UL Listed, RoHS Compliant, Title 20\/24 Compliant\u003c\/li\u003e\n  \u003cli\u003eManufacturer Part Number: ODS10-IQE\u003c\/li\u003e\n  \u003cli\u003eCountry of Origin: Mexico\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePassive Infrared sensing technology for reliable occupancy detection\u003c\/li\u003e\n  \u003cli\u003eAuto-ON\/Auto-OFF operation with no manual override to ensure energy savings\u003c\/li\u003e\n  \u003cli\u003ePhotocell controlled hold-OFF feature prevents unnecessary lighting in daylight\u003c\/li\u003e\n  \u003cli\u003eLow-profile Decora¬Æ style switch for aesthetic integration\u003c\/li\u003e\n  \u003cli\u003eAdjustable blinders to customize detection zones and reduce false triggers\u003c\/li\u003e\n  \u003cli\u003eCompatible with electronic and magnetic ballasts, incandescents, and fans\u003c\/li\u003e\n  \u003cli\u003eWide voltage compatibility supports multiple commercial and residential wiring standards\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads \u0026amp; Links\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_leviton\/2022q2\/documents\/9dac460786c6dda80d69885a4d49b212bfff5e28.pdf?did=4169\u0026amp;pid=1309373\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDI-02X-ODS10-40A-W.pdf\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_leviton\/2022q2\/documents\/04df4a11bf789c5ee3c13e96545f04b6ae6c1aba.pdf?did=4169\u0026amp;pid=1309373\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eApplication_Note_ULTRASONIC_AND_MULTI_TECH_ADA_FDA.pdf\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_leviton\/2022q2\/documents\/7f383182c97dcdbf18780227e311db3ae9d0714c.pdf?did=4169\u0026amp;pid=1309373\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eUSMCA_List_10292021.pdf\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_leviton\/2022q2\/documents\/0366da9f00966a5bdaa3024769d3c48928914cdc.pdf?did=4169\u0026amp;pid=1309373\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eSpec Sheet\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_leviton\/2022q2\/documents\/cee359645d89513eca72d4237ece1ba7b1109ea5.pdf?did=4169\u0026amp;pid=1309373\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eTech_Article-Occupancy_Sensing_and_Ballast_Life.pdf\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_leviton\/2022q2\/documents\/c8295eea2602370cc55743d148f13251d1bb4db7.pdf?did=4169\u0026amp;pid=1309373\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eTech_Article-PIR_and_US_Occupancy_Sensor_Technologies.pdf\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_leviton\/2022q2\/documents\/a84093e67f7ed6f36583a19d573e616806f4e177.pdf?did=4169\u0026amp;pid=1309373\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eApplication_Note_CHANGES_IN_TITLE_24.pdf\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_leviton\/2022q2\/documents\/ead4f6965bf1a0110c72acbd9ee9ba27cb290bbb.pdf?did=4169\u0026amp;pid=1309373\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eApplication_Note_READY_TO_ACHIEVE_LEED_POINTS.pdf\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_leviton\/2022q2\/documents\/f96bfb039e6b46c007c051dcd9daf26a89d02a51.pdf?did=4169\u0026amp;pid=1309373\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eApplication_Note_IRS_AND_ENERGY_MANAGEMENT.pdf\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_leviton\/2022q2\/documents\/bd8ce7ffcb29237420523160a75c9c1d2248ccf3.pdf?did=4169\u0026amp;pid=1309373\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eApplication_Note_ENERGY_POLICY_ACT_OF_2005.PDF\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_leviton\/2022q2\/documents\/1a7c722108cd4835438a84e6b0aafdbf70eef6ac.pdf?did=4169\u0026amp;pid=1309373\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eApplication_Note_IECC_VS_ASHRAE_90.1_2001.pdf\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_leviton\/2022q2\/documents\/6452098ecf8ca080b922b48a26eb6a08bf5b0284.pdf?did=4169\u0026amp;pid=1309373\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDI-02X-ODS10-50A_W.pdf\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_leviton\/2022q2\/documents\/0b3ef6637fac8fdf779767cc8e691d968369f5fd.pdf?did=4169\u0026amp;pid=1309373\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eOccupancy_Sensor_Technology_Intro.pdf\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_leviton\/2022q2\/documents\/87486903ee3b5431f189bc8d358c91db40bd979c.doc?did=4169\u0026amp;pid=1309373\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct_Specification_Bulletin_OCCUPANCY_SENSORS_AIA_SPECIFICATION_8-07.doc\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_leviton\/2022q2\/documents\/85e2988ebcb156050d465d45265610dbeeba77a9.pdf?did=4169\u0026amp;pid=1309373\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eTech_Article-Microphonics_and_Occupancy_Sensors.pdf\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_leviton\/2022q2\/documents\/050401c360acb2562e161d14fdc7e814f7b9897d.pdf?did=4169\u0026amp;pid=1309373\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDI-02X-ODS10-00A-W.pdf\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Leviton","offers":[{"title":"Default Title","offer_id":45854179918049,"sku":"34133","price":98.77,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0679\/9625\/4433\/files\/ffb30baf3fa6193dec40cc4eb42029915dda2ff0-large.png?v=1776500123","url":"https:\/\/ulegroup.com\/products\/occupancy-sensor-pir-wall-switch-2100sf-120-277v-black-auto-on-auto-off-only-decora-r","provider":"ULE Group","version":"1.0","type":"link"}