{"product_id":"leviton-ods0d-inr-pir-occ-snsr-2p-nft-red","title":"LEVITON ODS0D-INR PIR OCC SNSR 2P NFT RED","description":"\u003ch2\u003eLEVITON ODS0D-INR PIR Occupancy Sensor for Commercial Lighting Solutions\u003c\/h2\u003e\n\n\u003cp\u003eThe LEVITON ODS0D-INR is a commercial-grade occupancy sensor designed to detect motion and control lighting loads efficiently. Ideal for use by electrical distributors and lighting solutions providers, this device offers dual-circuit switching capability for two separate loads, enhancing energy savings in commercial environments. Its advanced passive infrared (PIR) technology provides reliable occupancy detection with a coverage area of up to 2100 square feet, making it suitable for large rooms such as conference rooms and classrooms. The sensor operates at 60 hertz frequency and includes a red LED indicator for status feedback. Certified to UL\/cUL standards and manufactured in Mexico, this occupancy sensor supports compliance with electrical codes and energy regulations.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eManufacturer Part #: ODS0D-INR\u003c\/li\u003e\n  \u003cli\u003eDevice Type: Occupancy Sensor\u003c\/li\u003e\n  \u003cli\u003eGrade: Commercial\u003c\/li\u003e\n  \u003cli\u003eColor: Red\u003c\/li\u003e\n  \u003cli\u003eCoverage Area: 2100 square feet\u003c\/li\u003e\n  \u003cli\u003eFrequency: 60 hertz\u003c\/li\u003e\n  \u003cli\u003eLED Color: Red\u003c\/li\u003e\n  \u003cli\u003eOperating Temperature: -10 degrees Celsius\u003c\/li\u003e\n  \u003cli\u003eCertifications: UL\/cUL\u003c\/li\u003e\n  \u003cli\u003eProduct Weight: 3.7 lbs\u003c\/li\u003e\n  \u003cli\u003eCountry of Origin: Mexico\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDual-circuit switching supports independent control of two lighting loads\u003c\/li\u003e\n  \u003cli\u003eAdvanced PIR sensor with dual pyrometers for enhanced motion detection and a 180° field of view\u003c\/li\u003e\n  \u003cli\u003eAdjustable time delay settings with factory default and user-configurable options\u003c\/li\u003e\n  \u003cli\u003eSelectable modes for conference room and classroom applications\u003c\/li\u003e\n  \u003cli\u003eVandal-resistant compact lens design for durability in commercial installations\u003c\/li\u003e\n  \u003cli\u003eAdjustable coverage range and ambient light sensing for optimized energy savings\u003c\/li\u003e\n  \u003cli\u003eManual override with push buttons to control lighting loads directly\u003c\/li\u003e\n  \u003cli\u003eAudible alarm tones to indicate operational status and delay warnings\u003c\/li\u003e\n  \u003cli\u003eComplies with California Title 24 energy efficiency requirements\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads \u0026amp; Links\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/leviton2\/2019q4\/48f3a0bd5a6b0d7446b122cd8447c53299fd5236.pdf?did=4169\u0026amp;pid=902562\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction Sheet - French\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/leviton2\/2019q4\/7920d89fd7a35085d00880a1e066f63dac4b42ba.pdf?did=4169\u0026amp;pid=902562\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eTechnical Article - PIR and US Occupancy Sensor Technologies\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/leviton2\/2019q4\/3a5ace9a7922c85d60364270be4af4412a00de22.pdf?did=4169\u0026amp;pid=902562\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eCompliance Letter - NAFTA\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/leviton2\/2019q4\/08ecf3de1191670f9d95e9ea288621390af489ba.pdf?did=4169\u0026amp;pid=902562\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eTechnical Article - Occupancy Sensors and Fluorescent Lamp Life\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/leviton2\/2019q4\/06766db46075c60cf6af58195647bb90de900fb6.pdf?did=4169\u0026amp;pid=902562\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eApplication Note - How Leviton is Ready to Help You Achieve Leed Points\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/leviton2\/2019q4\/f586eea775231dcedfa917560a5ea5e645620843.pdf?did=4169\u0026amp;pid=902562\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct Specification and Data Sheet\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/leviton2\/2019q4\/fe432359ba5161f5b189e844aa93e6815a2aa260.pdf?did=4169\u0026amp;pid=902562\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eTechnical Article - Microphonics and Occupancy Sensors\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/leviton2\/2019q4\/8ff68d8b813e06b647b0354abdc1da8e27482018.pdf?did=4169\u0026amp;pid=902562\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eApplication Note - Energy Policy Act of 2005\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/leviton2\/2019q4\/1acb10823fad60f7814224140103d8192c20c7d9.pdf?did=4169\u0026amp;pid=902562\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction Sheet - Spanish\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/leviton2\/2019q4\/09dc507deea04991a5e20f440e5573da7019c4c0.pdf?did=4169\u0026amp;pid=902562\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eApplication Note - IECC VS ASHRAE 90.1-2001\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/leviton2\/2019q4\/a4105e10701f449901b64d80549fe5e863ca4c2f.doc?did=4169\u0026amp;pid=902562\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eSpecification (AIA) - Occupancy Sensors\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/leviton2\/2019q4\/f390f4aa89a209eeef65e69746aa92af697a738b.pdf?did=4169\u0026amp;pid=902562\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eReference - Occupancy Sensor Technology Intro\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/leviton2\/2019q4\/7c22814427728aad785a4da837f16a9196af054a.pdf?did=4169\u0026amp;pid=902562\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction Sheet\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/leviton2\/2019q4\/2729ecd2af2d311fa300fcfe60a3020c119d5814.pdf?did=4169\u0026amp;pid=902562\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eApplication Note - ADA and FDA Ultrasonic and MultiTechnology\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/leviton2\/2019q4\/27695daeba74a210bdfaf444ce3508ed3c0495f6.pdf?did=4169\u0026amp;pid=902562\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eApplication Note - IRS AND ENERGY MANAGEMENT OFFICIAL STATEMENT\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/leviton2\/2019q4\/718e6dbc3a722f1ae97cfe2624f5cd2d8decd522.pdf?did=4169\u0026amp;pid=902562\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eApplication Note - Changes in Title 24\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Leviton","offers":[{"title":"Default Title","offer_id":45854431117537,"sku":"33982","price":128.69,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0679\/9625\/4433\/files\/da27645b2d9f5878f27fe5716b549641897abc9d-large.png?v=1776501360","url":"https:\/\/ulegroup.com\/products\/leviton-ods0d-inr-pir-occ-snsr-2p-nft-red","provider":"ULE Group","version":"1.0","type":"link"}