{"product_id":"eaton-series-c-complete-molded-case-circuit-breaker-k-frame-kdc-fixed-thermal-fixed-magnetic-trip-three-pole-400a-600-vac-250-vdc-200-kaic-at-240-vac-100-kaic-at-480-vac-aluminum-line-and-load-50-60-hz","title":"Eaton Series C complete molded case circuit breaker, K-frame, KDC, Fixed thermal, fixed magnetic trip, Three-pole, 400A, 600 Vac, 250 Vdc, 200 kAIC at 240 Vac, 100 kAIC at 480 Vac, Aluminum, Line and load, 50\/60 Hz","description":"\u003ch2\u003eEaton Series C Complete Molded Case Circuit Breaker - Circuit Protection\u003c\/h2\u003e\n\n\u003cp\u003eThe Eaton Series C complete molded case circuit breaker, K-frame, KDC type, is designed for reliable circuit protection in industrial and commercial electrical distribution systems. This three-pole breaker supports 400 amperes at 600 Vac and 250 Vdc, with a high interrupting capacity of 200 kAIC at 240 Vac and 100 kAIC at 480 Vac. It is constructed with aluminum components for both line and load connections and operates at 50\/60 Hz, making it suitable for power distribution, motor control, and lighting solutions applications. As an electrical distributor or switchgear supplier, Eaton provides this breaker for robust system protection and coordination within wire and cable networks.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n\u003cli\u003eManufacturer Part #: KDC3400\u003c\/li\u003e\n\u003cli\u003eFrame: K\u003c\/li\u003e\n\u003cli\u003eAmperage: 400 amperes\u003c\/li\u003e\n\u003cli\u003ePoles: Three-pole\u003c\/li\u003e\n\u003cli\u003eVoltage Rating: 600 Vac, 250 Vdc\u003c\/li\u003e\n\u003cli\u003eInterrupting Capacity: 200 kAIC at 240 Vac, 100 kAIC at 480 Vac\u003c\/li\u003e\n\u003cli\u003eMaterial: Aluminum\u003c\/li\u003e\n\u003cli\u003eFrequency: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 5.5 in x 5.5 in x 4.1 in\u003c\/li\u003e\n\u003cli\u003eProduct Weight: 13.34 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFixed thermal and fixed magnetic trip units for precise and reliable circuit interruption\u003c\/li\u003e\n\u003cli\u003eCurrent limiting capability to enhance system protection by reducing fault current\u003c\/li\u003e\n\u003cli\u003eSuitable for line and load applications with aluminum construction\u003c\/li\u003e\n\u003cli\u003eHigh interrupting ratings support system safety and coordination\u003c\/li\u003e\n\u003cli\u003eCompact design with standardized frame size for easy integration\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDownloads \u0026amp; Links\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_eaton\/2022q1\/documents\/5c9e58514a4dd8a29787f344b1c602b25dcafb49.pdf?did=4169\u0026amp;pid=1598220\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eCurrent Limiting Series C Molded Case Circuit Breakers Product Aid\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_eaton\/2022q1\/documents\/d628119b7619457fe6951f8984eca3f9b43f71ca.dwg?did=4169\u0026amp;pid=1598220\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eKdc3 Autocad 2D Footprint\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_eaton\/2022q1\/documents\/952bb8524675434d53aed28e5c20f5511ae9b6c2.pdf?did=4169\u0026amp;pid=1598220\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eSeries C G-Frame Molded Case Circuit Breakers Time Current Curves\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_eaton\/2022q1\/documents\/9cadb9bef64362342ef2259f57ad8a6d93ad6f42.pdf?did=4169\u0026amp;pid=1598220\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eMoem Mccb Product Selection Guide\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_eaton\/2022q1\/documents\/76dc54544bec6350ceed6199147b989fa9537784.pdf?did=4169\u0026amp;pid=1598220\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eMulti-Wire Lugs Product Aid\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_eaton\/2022q1\/documents\/69ab9278348e9d8833c06fe28a472a14553d8edb.pdf?did=4169\u0026amp;pid=1598220\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eCircuit Breaker Motor Operators Product Aid\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_eaton\/2022q1\/documents\/26170709fea69c05f1ba9c404099a929d58264c0.pdf?did=4169\u0026amp;pid=1598220\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eStrandable Terminals Product Aid\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_eaton\/2022q1\/documents\/781be5cca65d4063ef4d1ceb29c8c9fcdbfa085f.pdf?did=4169\u0026amp;pid=1598220\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eMolded Case Circuit Breakers Catalog\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_eaton\/2022q1\/documents\/03e2a660c250d6b6742f303f4d2faf0c5d464428.pdf?did=4169\u0026amp;pid=1598220\" target=\"_blank\" rel=\"noopener noreferrer\"\u003ePlug-In Adapters For Molded Case Circuit Breakers Product Aid\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_eaton\/2022q1\/documents\/b85ee253e6ef5a7cabee4b1b89f0e5ebac24fd8d.pdf?did=4169\u0026amp;pid=1598220\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eSeries C F-Frame Molded Case Circuit Breakers\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_eaton\/2022q1\/documents\/41e79099115e9b0c563009dc57105ba76b593c64.pdf?did=4169\u0026amp;pid=1598220\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction Leaflet For The Kes 310+ Electronic Trip Unit\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_eaton\/2022q1\/documents\/8436b4095d4ab8fd4750ad48438535190c7e3fc5.pdf?did=4169\u0026amp;pid=1598220\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eBreaker Service Centers\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_eaton\/2022q1\/documents\/52a8c463d75652e3db53003ec7e763182753e770.pdf?did=4169\u0026amp;pid=1598220\" target=\"_blank\" rel=\"noopener noreferrer\"\u003ePower Metering And Monitoring With Modbus Rtu Product Aid\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_eaton\/2022q1\/documents\/27997c5c82a0163285f77bcf5b09ade4e46b96f3.pdf?did=4169\u0026amp;pid=1598220\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eApplication Of Multi-Wire Terminals For Molded Case Circuit Breakers\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_eaton\/2022q1\/documents\/6be5c7dd01158e0dc199d94dfada24ba8ad0b411.pdf?did=4169\u0026amp;pid=1598220\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eSeries C J-Frame Molded Case Circuit Breakers Time Current Curves\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_eaton\/2022q1\/documents\/d5814d7bb63b60b52da62f0c8bfa0eba511ac527.pdf?did=4169\u0026amp;pid=1598220\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eMoem Mccb Product Selection Guide\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_eaton\/2022q1\/documents\/c33d06c1c45872b3a452b15bf458f5653390201a.dwg?did=4169\u0026amp;pid=1598220\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eKdc3 Autocad 2D Footprint (Mm)\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_eaton\/2022q1\/documents\/f3d6aebb1434b33d9a60b8e232eb3ef7ac0f8ad8.pdf?did=4169\u0026amp;pid=1598220\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eMotor Protection Circuit Breakers Product Aid\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_eaton\/2022q1\/documents\/5584052923d7d2f3f2b823086089a7f5941a879b.pdf?did=4169\u0026amp;pid=1598220\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eKdc3 2D Pdf\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_eaton\/2022q1\/documents\/252b2bb86cce85a50274eda0ca7d81a8d68a4dc5.pdf?did=4169\u0026amp;pid=1598220\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eF-Frame 310+ Molded-Case Circuit Breakers 15-225A\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_eaton\/2022q1\/documents\/f286170a9c19d93a6714f62f05d2952de7c0d27d.pdf?did=4169\u0026amp;pid=1598220\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eApplication Of Tap Rules To Molded Case Breaker Terminals\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_eaton\/2022q1\/documents\/4677257efc11b5bcf507481042494c4a99ec087c.dxf?did=4169\u0026amp;pid=1598220\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eKdc3 2D Drawing Xchange\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_eaton\/2022q1\/documents\/9a83e8acac076643256eced127ee1baf151206dd.stp?did=4169\u0026amp;pid=1598220\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eKdc3 3D Model Xchange\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_eaton\/2022q1\/documents\/5b1df23333760d2456205f02baaadeda16cac638.pdf?did=4169\u0026amp;pid=1598220\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eEatons Volume 4-Circuit Protection\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_eaton\/2022q1\/documents\/15bc279622fff250ce63327b50ad66a462c976f0.ipt?did=4169\u0026amp;pid=1598220\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eKdc3 3D Inventor\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/csv_eaton\/2022q1\/documents\/e736a9a2f438846c6f92c5a0b0d5cfd357327f4a.pdf?did=4169\u0026amp;pid=1598220\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstallation Instructions For Dk, Kdb, Kd, Hkd, Kdc, Kw, Hkw, Kwc, Ckd, Chkd Circuit Breakers And Molded Case Switches\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":45856315769057,"sku":"166881","price":13790.6,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0679\/9625\/4433\/files\/b4a2aeb0c810559241953c454e81e4f96b88e06b-large.png?v=1780359600","url":"https:\/\/ulegroup.com\/products\/eaton-series-c-complete-molded-case-circuit-breaker-k-frame-kdc-fixed-thermal-fixed-magnetic-trip-three-pole-400a-600-vac-250-vdc-200-kaic-at-240-vac-100-kaic-at-480-vac-aluminum-line-and-load-50-60-hz","provider":"ULE Group","version":"1.0","type":"link"}